HRLE, Basic Dual Channel Chiller for Lasers

The HRLE is a temperature control device featuring two independent cooling channels in one package.  This thermo chiller is designed to cool the optical head and oscillator of a laser processing system.  Considerable space savings can be realized compared to a two chiller solution.  All operation can be managed from a single touch panel.  Compared to the HRL, the HRLE targets medium-sized 3-4kW lasers and simplifies the internal components.  Heat extracted by the refrigerant cycle can be either cooled with a fan (air type) or with facility water (water type).  Space and energy are saved using a single fan (air type), compressor, pump and tank.  The heating function uses waste heat from the refrigerant discharge instead of a separate electric heater to improve efficiency and reliability.  Several features are optional to reduce the cost of the basic unit.  These options include DI water capability, electrical conductivity control kit, bypass piping, automatic water fill kit, particle and fluid fill filters, and a ball valve set for adjusting coolant pressure and flow rate.

  • Total cooling capacity: 9.5kW (air)/11.0kW (water) (CH1 oscillator, CH2 optical system combined)
  • Power supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase
  • Power supply "40"; 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase
  • Temperature set range: CH1 = 15 to 25°C, CH2 = 0 to 15°C
  • Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C
  • Refrigerant: R410A
  • Communication: contact/analog I/O; Serial RS-485
HRLE, Basic Dual Channel Chiller for Lasers
Configuration Options
  
 
Copy Configuration Number

Product Options

Select Product Options
Select values from the drop down lists or make appropriate selections to configure the part number.
Cooling Capacity Configuration Status
Cooling Method Configuration Status
Power Supply Configuration Status
Option Configuration Status
Options in:
  • Gray are not compatible with other selected option value.
  • Red conflict with another selected option value.
  • Amber are not recommended.

Downloads

The part number needs to be complete in order to view/download CAD Models.

Model does not exist, please email cad@smcusa.com with the complete part number, CAD file format and version required.

CAD is not currently available for auto generation of . The file can be requested by contacting CAD@smcusa.com

CAD Downloads

Download CAD File

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate